OptoPlex

The Plexon OptoPlex LED-based optical stimulation system is an afforable, turn-key solution for optogenetic experiments. Using new LED-fiber coupling technology, the OptoPlex system can deliver power output comparable to that of high-priced lasers. With the LED light source, the OptoPlex system provides more constant light output over time compared to many laser systems, which suffer from transient fluctuations at onset and varying light output over time due to temperature changes.

 



The Plexon OptoPlex light stimulation system is a flexible optogenetic stimulation solution, and is available in multiple wavelength options - 460/470, 525, 590, and 615/625 nm. The LED module can be configured with either 125/140 µm or 200/230 µm (ID/OD) fibers for use in both chronic and acute preparations. All necessary accompanying interconnects and implantable ferrules are availabel through Plexon.

 

 

 

 

The Plexon OptoPlex LED-based Optogenetic Stimulation System features include:

 

  • Laser-like power output at an afordable price
  • Compact
  • Multiple wavelengths available (460/470, 525, 590, 615/625 nm)
  • Digital input to trigger from external device
  • Analog input for arbitrary amplitude modulation
  • Steady luminance output over time
  • Configurations for both acute and chronic experiments

 

LED Modules  
Wavelengths
460/470 nm (blue), 525 nm (green),
590 nm (amber), 615/625 nm (red)
Fibers
8.2 x 2.8 x 4.1 in
Fibers
2.0 lbs
Weight Power Supply 2.5 lbs
Power Requirements 100-240 VAC, 47-63 Hz, 0.96-0.51 A
Operating Systems Windows 7, Windows XP
Computer Interface USB 2.0
Stim Out connector 26 pin Harwin, Male
Digital Out Connector 20 pin Harwin, Male
Digital In Connector 20 pin Harwin, Male
Voltage monitor channel output BNC
Current Monitor Channel Output BNC
Interface (connection to computer) USB 2.0
Stimulation cable – version 1 (other versions available upon request) 26 pin Harwin, Female to 20 pin Omnetics .050, Female
   
Analog Outputs  
Stimulation Mode Constant Current
Number of analog output channels 16 outputs, 1 return
Maximum Current ±1 mA (Stimulation mode)
Resolution 16 bits
Output current resolution 30 nA (Stimulation mode)
Compliance voltage 10 V @ 700 µA
Temporal resolution 1 µsec
Output rise time (10-90 %) voltage 1.25 µsec (100 µA, 10 kΩ load)
Minimum pulse width 5 µsec
Minimum pulse rate 1.25 µsec (100 µA, 10 kΩ load)
Maximum pulse rate 100 kHz
   
Digital inputs/outputs  
Number of digital inputs 16
Number of digital outputs 17
Digital Input Levels TTL, Low < 0.8V, High > 2.0V
Digital Output Levels HCT, Low < 0.33V, High > 3.84V
Digital input/output latency < 1 µsec
Maximum trigger rate 100 kHz
Minimum trigger pulse width 1 µsec
   
Arbitrary Waveforms  
Maximum Sample Points 1000
Maximum update rate 1 MHz (1 µsec)
   
Impedance Test  
Supplied Current 1 kHz ±100 nA sine wave

030206


Loading...